177230-02-01-05 | Bently Nevada 0-50.8 mm/s Seismic Transmitter

✓ In Stock
Part No. 177230-02-01-05
Condition In Stock
Weight 0.5 kg
100% New & Original
12 Month
Fast Worldwide Shipping

Introduction to the Bently Nevada 177230-02-01-05 Seismic Transmitter

When you need accurate vibration monitoring for rotating machinery, the 177230-02-01-05 from Bently Nevada provides a dependable solution. This seismic transmitter converts vibration into a standard 4-20 mA current loop signal, making it easy to integrate with your existing PLC, DCS, or SCADA systems. Its rugged 316L stainless steel case and hermetic seal ensure long-term performance in harsh industrial environments.

Figure 1: Front view of the Bently Nevada 177230-02-01-05 industrial automation component showing its physical design and enclosure.

Key Features and Technical Specifications

The 177230-02-01-05 is designed for continuous vibration monitoring. Here are the essential specifications you can rely on:

  • Measurement Range: 0 to 50.8 mm/s (0 to 2.0 in/s) RMS
  • Frequency Range: 10 Hz to 1 kHz (600 to 60 kcpm) RMS
  • Output Signal: 4-20 mA current loop (proportional to peak vibration)
  • Excitation Voltage: 12 to 30 Vdc, current limited to 40 mA
  • Settling Time: Less than 15 seconds within 2% of final value
  • Mounted Resonant Frequency: Greater than 12 kHz
  • Transverse Sensitivity: Less than 5% of sensitivity
  • Sensing Element: Ceramic / shear type
  • Case Material: 316L stainless steel
  • Connector: 3-pin MIL-C-5015, 316L stainless steel
  • Mounting Hole: 1/4-28 UNF (also M6 X 1 SI and M8 x 1.25 SI threads)
  • Operating Temperature: -40°C to +85°C (-40°F to +185°F)
  • Relative Humidity: Up to 100% non-submerged
  • Weight: 0.131 kg (4.62 oz)

One distinctive feature is the dynamic acceleration signal available on Pin C, which provides an unbuffered signal referenced to Pin B. This allows you to capture additional vibration data beyond the standard 4-20 mA loop, offering deeper insight into machine health.

Applications and Use Cases

The 177230-02-01-05 is ideal for monitoring vibration on fans, pumps, motors, and other rotating equipment. Its 4-20 mA output integrates seamlessly with most control systems, enabling continuous condition monitoring without specialized hardware. For example, in a predictive maintenance program, you can use the transmitter to trend vibration levels over time, detecting bearing wear or imbalance before they cause downtime. Moreover, its compact size and robust construction make it suitable for installation in tight or demanding locations.

Figure 2: Technical layout and connection details for the Bently Nevada 177230-02-01-05 industrial automation component.

Installation and Setup

Mounting the 177230-02-01-05 is straightforward. The unit features a 1/4-28 UNF mounting hole, and you can also use M6 or M8 metric threads if preferred. Apply a mounting torque of 4 to 7 N-m (35.4 to 62.0 in-lbf) to ensure a secure fit. The 3-pin MIL-C-5015 connector simplifies wiring: Pin A is the 4-20 mA positive loop, Pin B is the loop return (common), and Pin C provides the dynamic acceleration signal. Ensure your power supply is current-limited to 40 mA, as the transmitter is designed for systems with internal power supplies typically limited to 30-35 mA.

Maintenance and Reliability

Thanks to its hermetically sealed sensor and 316L stainless steel construction, the 177230-02-01-05 requires minimal maintenance. However, periodic inspection is recommended to verify that the mounting remains tight and the connector is clean and secure. The transmitter can withstand up to 100% relative humidity (non-submerged) and operates reliably in temperatures from -40°C to +85°C. With proper care, this unit offers long service life, reducing your total cost of ownership.

Compatibility and Integration

The 177230-02-01-05 is designed for use with PLCs, DCS, and SCADA systems that have internal power supplies. Its 4-20 mA output is universally accepted, making integration straightforward. The dynamic signal on Pin C can be connected to a data acquisition system for advanced analysis. This flexibility ensures the transmitter fits into both new and existing monitoring architectures.

Troubleshooting and Common Issues

If you experience no output signal, first verify that the excitation voltage is between 12 and 30 Vdc and that the current is limited to 40 mA. Check the wiring: Pin A should be positive, Pin B negative. If the signal is noisy, ensure the mounting is secure and the sensor is not subjected to excessive transverse vibration. For persistent issues, consult the official Bently Nevada documentation or contact Petro Auto Tech for technical support.

FAQ about the 177230-02-01-05

Q: What is the measurement range of the 177230-02-01-05?

A: The measurement range is 0 to 50.8 mm/s (0 to 2.0 in/s) RMS.

Q: What output signal does the transmitter provide?

A: It provides a 4-20 mA current loop output proportional to peak vibration levels.

Q: Can the 177230-02-01-05 be used in hazardous areas?

A: Yes, it has multiple approvals including CSA/NRTL/C and ATEX/IECEx, making it suitable for hazardous locations.

Q: What is the operating temperature range?

A: The operating temperature range is -40°C to +85°C (-40°F to +185°F).

Q: How do I mount the transmitter?

A: Use the 1/4-28 UNF mounting hole or M6/M8 threads, with a mounting torque of 4 to 7 N-m.

Product Support and Availability

The 177230-02-01-05 is available from Petro Auto Tech, your trusted industrial automation parts supplier. We ensure genuine Bently Nevada products are in stock and ready to ship. Contact our team for pricing and availability.