Product Summary
The Flexem FR-ECAT acts as a vital gateway for your automation network. This EtherCAT bus coupler connects field devices to a high-speed control system. It supports a wide power input range from 9 to 36 VDC. The module also provides reliable isolation for signal integrity. Engineers can extend their system with up to 31 additional modules. This design makes the FR-ECAT a flexible choice for distributed architectures.
Expert Technical Evaluation & Performance Review
The Flexem FR-ECAT delivers robust performance for demanding industrial environments. It operates reliably within a temperature range of -20 to 70 degrees Celsius. The module also withstands ambient humidity levels from 5% to 95% non-condensing. This tolerance ensures stable operation in harsh factory conditions. The device consumes only 110mA at 24Vdc, which keeps energy costs low. Its IP20 protection grade suits installation inside a control cabinet.
The FR-ECAT supports the EtherCAT protocol for real-time data exchange. It processes input data areas up to 1024 bytes and output data areas up to 1024 bytes. This capacity handles complex control tasks with minimal latency. The dual RJ45 connectors operate at speeds of 10/100 Mbps. Each connection can span a maximum cable length of 100 meters. This configuration meets the needs of high-speed, deterministic networks.
The unit includes essential protection features for system safety. It offers overcurrent protection to prevent damage from electrical faults. The anti-reverse connection protection safeguards the module during wiring. These features reduce the risk of costly downtime and repairs. The field power supply ranges from 22 to 28 volts with a normal 24VDC. The field power current supports a maximum of 8 amps DC.
Step-by-Step User & Installation Guide

Installing the Flexem FR-ECAT follows a straightforward process for any technician. First, mount the unit onto a standard 35mm DIN rail. The device dimensions are 111mm in height, 36mm in width, and 76mm in depth. Ensure the rail is securely fastened to the back panel. The module weighs only 200 grams, making it easy to handle.
Next, connect the power supply to the designated terminals. Use wire with a maximum cross-section of 1.5mm² or AWG 16. Verify the input voltage is between 9 and 36 VDC. The normal operating voltage is 24 VDC for standard applications. Check the polarity to ensure the anti-reverse protection works correctly.
Then, wire the field power supply to the appropriate connectors. The field power voltage must stay between 22 and 28 volts. Confirm the total field current does not exceed 8 amps. This step prevents overloads and ensures stable operation.
Finally, connect the EtherCAT network cables to the two RJ45 ports. Use standard Ethernet cables for the network connection. The maximum cable length between devices is 100 meters. This setup allows for a daisy-chain topology in your network. The system can support up to 31 extension modules on the bus.
Deep-Dive Technical FAQ
Question 1: What is the maximum current for the field power supply?

The FR-ECAT supports a maximum field power current of 8 amps DC. You must ensure your connected devices do not exceed this limit. Exceeding this value can trigger the overcurrent protection feature.
Question 2: Can I use this module in a high-temperature environment?
Yes, the FR-ECAT operates effectively in temperatures from -20°C to 70°C. This range covers most standard industrial applications. Ensure the ambient humidity stays between 5% and 95% non-condensing.
Question 3: How many extension modules can the FR-ECAT support?
This bus coupler supports a maximum of 31 extension modules. This capacity allows for significant system expansion. You can build a comprehensive I/O network with this single coupler.
Question 4: What is the total data throughput for the process data area?

The FR-ECAT handles a maximum of 1024 bytes for input and 1024 bytes for output. This data area supports complex and fast control loops. The 10/100 Mbps speed ensures low latency for critical processes.
Question 5: What type of wire gauge is recommended for connections?
The module accepts wires with a maximum size of 1.5mm² or AWG 16. This gauge provides a secure and reliable electrical connection. Use proper ferrule connectors for stranded wire to ensure a tight fit.